Product code: 0024
Description
PS-101T is a safety device of one channel used for the exhaust confirmation of the miss feed detection or the product.
Features
The timing signal from the press, both the limit switch and the adjacent switch are also possible. |
Two functions are installed in the Passage detection unit. |
The timing signal circuit is equipped with the timing timer function. |
Specification
Detection channels |
1 |
Detection mode |
Passage (modes1,2) |
Voltage of detection circuit |
DC12 V |
Timing mode |
Timer timing (25 ms ~ 2.5 s) |
Voltage of timing circuit |
DC12 V |
Stop output circuit |
Relay output AC200 V 2 A (max.) |
Stop output delay time |
Approx. 25 ms |
Power supply voltage |
AC100 V ~ 200 V |
Ambient operating temperature |
0 to 55 degree C (No sudden temperature change during the use.) |
Dimensions(WHD) |
170 * 49 * 146 mm (An umbo is not included.) |
Weight |
Body 1.9 kg (inc. mounting brackets.) |
Power consumption |
Approx. 7 VA |
Attachments |
Output cable (Standard: 5 m) |